Colorado has adopted the 2024 editions of the International Plumbing Code (IPC) and International Residential Code (IRC), along with designated provisions of the International Fuel Gas Code (IFGC), subject to Colorado-specific amendments. Together, these provisions form the Colorado Plumbing Code and Colorado Fuel Gas Code.
The adopted rules and state amendments are available through the Colorado Secretary of State’s Code of Colorado Regulations.
These updates matter to everyone working in the trade, not just as a matter of staying current. The changes affect day-to-day practice – how jobs are supervised, when permits must be pulled, how systems are tested, and how contractors identify themselves on vehicles, bids, and advertising. The Board conducts compliance checks across the state, with priority on critical projects such as schools, hospitals, and public buildings, so gaps are more likely to be caught. Falling behind on the new requirements can mean failed inspections, project delays, fines, and even license suspension, while staying current protects public health and safety and keeps work moving. Reviewing these changes now helps plumbers, contractors, and design professionals avoid those consequences and plan for requirements still phasing in.
Contractors, plumbers, and design professionals should review their standard details, inspection checklists, and compliance materials in light of the updated Colorado codes and amendments. Particular attention should be directed to:
- Revised testing protocols for plastic piping and plastic water-heater vents.
- Backflow-preventer testing at installation, after repair or relocation, and annually.
- Required labeling, signage, dye, and backflow protection for nonpotable-water and graywater systems.
- Updated requirements for cleanouts, garage and utility-building drains, and roof-vent terminations.
- Contractor-registration and master-plumber license-number displays on vehicles, documents, websites, and online advertisements.
Because local enforcement practices and project-specific conditions may vary, project teams should confirm applicable requirements with the authority having jurisdiction before beginning work.
The following summarizes several changes most likely to affect plumbers, contractors, design professionals, and property owners.
Direct Supervision of Apprentices
State law requires an apprentice plumber to work under the direct supervision of a licensed plumber. “Direct supervision” means that the supervising plumber must be physically present at the permitted address where the apprentice is working, or within five minutes of the apprentice on the same job site. A licensed plumber may supervise no more than three apprentices at the same job site, and supervising more than three is itself a violation subject to a fine.
Emergency Permits
For emergency plumbing work – such as repairs to broken water or drain lines, or replacement of a water heater – a permit may be obtained on the next business day after work begins.
Contractor Credential Display
Effective July 1, 2025, plumbing contractors must display the company’s contractor-registration number and the responsible master plumber’s license number on company vehicles, bid documents, billing materials, websites, and online advertisements.
Vehicle markings must appear in at least two locations and use characters at least two inches high. Contractors must update the required information within 90 days after a change.
Testing and Inspection
The amendments streamline several plumbing-system testing requirements. They remove provisions that treated plastic piping differently from other piping materials, including the “other than plastic” limitation and the blanket prohibition on air testing plastic systems when air testing is otherwise permitted.
Backflow-preventer assemblies must still be tested at installation, after repair or relocation, and at least annually. A certified cross-connection control technician must perform each test.
The fuel-gas rules also expressly subject temporary-heating installations to inspection and pressure testing. Where plastic vent piping is used to vent a gas-fired water heater, the venting system must be pressure-tested before the appliance is connected.
Nonpotable Water and Graywater
Nonpotable-water distribution piping must be purple, or fully wrapped in purple identification material, and marked: “CAUTION: NONPOTABLE WATER—DO NOT DRINK.” Fixtures supplied with nonpotable water must carry the required caution signage. Fixtures that collect graywater must also display a reuse warning.
Graywater used for toilet or urinal flushing must be colored with blue or green food-grade dye and must be readily distinguishable from potable water. Systems using nonpotable-water reuse must include a reduced-pressure backflow preventer at the building service.
The amendments also remove rainwater-system provisions. Project teams should confirm the requirements applicable to any proposed rainwater or alternative-water-reuse system with the authority having jurisdiction.
Drainage, Venting, and Accessibility
The updated rules make several targeted changes to drainage and venting details that may affect both plan review and field inspections:
- Drainage definitions. The definitions of “trap drain” and “fixture drain” are clarified to better distinguish the trap arm from downstream drainage piping.
- Building drain and sewer cleanouts. Cleanouts at the building-drain/building-sewer junction must use a two-way configuration, subject to applicable depth and material limits. They also must be installed and tested during the underground or rough-in stage.
- Utility-building and garage drains. Floor or trench drains in utility buildings and residential garages may be permitted to daylight or discharge to an approved alternative disposal system, but only with written approval from the authority having jurisdiction, the Colorado Department of Public Health and Environment (CDPHE), or the applicable sewer purveyor.
- Sand-oil interceptors. Trench and floor drains discharging to a sand-oil interceptor do not require individual traps if the discharge turns down at least four inches below the interceptor’s standing water level.
- Roof vent terminations. Roof vents must terminate at least six inches above the roof. Where roof panels protect or cover the vent, the vent must extend at least four inches above the roof surface.
New construction and remodeling projects for state and local government entities, other than K–12 schools, must provide ADA-compliant single-user or multi-user all-gender restrooms when required by statute. The rules also prohibit service sinks and mop sinks in toilet rooms, bathing rooms, and food-preparation areas.
Fuel-Gas Requirements
Welded gas-piping joints require a qualifying certificate under ASME Section IX and must comply with ASTM A139. Plastic gas-piping bends must have an inside radius of at least 25 times the pipe’s inside diameter.
Penalties for Violations
Violations of the Board’s rules can lead to three types of penalties. First, the Board can take administrative action: issuing a citation with a fine, placing a license on probation, or suspending or revoking it. It can also order a plumber or contractor to stop work that poses a threat to public safety or that is being done without a license. Second, the Board can go to court for an injunction. If a plumber or contractor ignores a stop-work order, the state can ask a court to order them to halt the violation, and a plumber who disobeys that court order can face further court penalties. Third, performing plumbing work without a license is a crime (a class 2 misdemeanor), which carries its own penalties in addition to any Board action.
Fine amounts increase with repeat violations. Under the Board’s fine schedule, effective April 30, 2025, a first offense may carry a fine of up to $1,000, a second offense up to $2,000, and any continuing or subsequent offense up to $2,000 for each day the violation continues. Paying a fine does not excuse correcting the underlying violation. A plumber who receives a citation has ten working days to pay the fine, request a settlement, or request a hearing; otherwise the citation becomes final and binding.